A ClassCastException has occurred on Windows XP while adding subreport.
Formula Editor: NullPointerException has occurred after double click on a node (e.g. “Database Fields”) instead of a field.
Field browser has not been refreshed if a field had been added or if a report was opened or created and a report has already existed.
Database connections with a password which is not empty caused a NullPointerException before an export because the password had not been serialized and the connection could not been re-established.
Parameter field: An entered default value could not be removed.
Menu items in menu “Report” were disabled in subreports if the main report had no database connection.
Database Wizard: Tables and Stored Procedures could not be removed by pressing the “DEL” key.
Field browser: Database fields had been sorted alphabetically. Now they are listed like they appear in the database.
Chart properties can now be edited directly after the chart has been added.
Section have been displayed wrong if you had more than 26 sections.
Sections property dialog could have grown over screen size if you had a large number of sections.
Sybase: Stored Procedures with parameters could not bee added.
EditorPage has not been updated if an field was deleted in the fieldbrowser.
Settings for margins were disabled in the “Page Layout” if user defined labels were selected.
A database field added to EditorPage was to small, minutes and seconds were truncated.
Fields added to the EditorPage have not been aligned to the grid.
Elements (except fields) added to the EditorPage could have caused an enlargement of the section in y-direction.
In the section properties dialog the current section has not been selected.
It was possible to set no-line property for a line object which does not make any sense.
Elements could have been moved to a negative x-position in some cases.
Box elements caused an error if they were resized over multiple sections.
User-defined page layout could not be used.
Prompt properties: It was possible to enter invalid default values.
Prompt properties: Changes to properties had not been considered in every case for undo/redo actions.
Shadow of box elements remained although the rounded corners were selected.
Inputs in the AddSubReport dialog had not been checked for errors.
SQL-expressions: Changes to a
SQL-expression had not been considered for undo/redo actions.
A Section remained marked as suppressed in the editor page if the Suppress-Formula for this section has been deleted.
Changes to an TextObject had not been noticed if editing was not stopped explicitly before saving or closing.
NullPointerException could occur using Oracle Stored Procedure without parameters.
Using hyperlink formulas could have caused corrupt reports.
Changes to zoom settings had not been saved for undo/redo.
Double click on TextObject caused scroll to the top of the report.
Bug with crosstab grid lines has been fixed.
Multiple bugs in the crosstab design view has been fixed.